BOD Incubator, Digital

Availability:

In Stock


The BOD-D series comprises precision, temperature-controlled incubators designed for biochemical oxygen demand (BOD) testing, using PID control and forced air circulation to maintain stable, uniform temperatures for continuous laboratory operation.

Features: 

  • Microprocessor-based PID temperature control
  • Programmable PID controller with 128 × 64 STN monochrome graphic display
  • Temperature deviation alarm with audio/visual indication
  • Door-open alarm for process safety
  • Free-running or timed operation with power-failure recovery options
  • Low-noise operation and energy-efficient design
  • Adjustable stainless-steel mesh trays
  • LED interior illumination
  • Double-door construction with inner toughened-glass door
  • Door safety cut-off and over-temperature thermostat
  • Validation port for external temperature monitoring
  • Optional RS485 PC interface and 21 CFR compliance software for online data recording with date-time stamping

Technical Specifications:

  • Temperature Range: +10°C to +60°C
  • Temperature Resolution: 0.1°C
  • Temperature Accuracy: ±1°C
  • Temperature Uniformity: ±1°C
  • Controller: Microprocessor-based PID
  • Timer range: 5 seconds to 999 hours
  • Sensor: 3-wire RTD PT100
  • Display: 128 × 64 STN monochrome graphic display
  • Air Circulation: Forced air circulation
  • Cooling System: Hermetically sealed, CFC-free compressor
  • Inner Chamber Material: SS-304
  • Power Supply: 230 V AC, 50 Hz
  • Safety: Over-temperature thermostat, door safety cut-off, leakage-current protection, and fuse / MCB protection according to capacity
BOD-D

Cat. No.Capacity, LPower, WChamber SizeShelvesPack SizeQuantity 
BOD-D-120L1201000450 × 450 × 600 mm21
BOD-D-210L2101300600 × 600 × 600 mm21
BOD-D-320L3201600600 × 600 × 900 mm31
BOD-D-500L5002000650 × 650 × 1200 mm31
BOD-D-700L7002400750 × 700 × 1350 mm41

Scope of Supply

  • Main unit
  • Instruction manual
  • Power cord
  • Adjustable stainless-steel mesh trays as per selected model
    IQ/OQ documentation
    Sensor and controller calibration certificates (NABL; non-NABL for certain sensors and controllers)
    Factory test report
    Optional, supplied only when ordered: perforated stainless-steel trays and SS304/SS316 inner and outer body construction
    Optional, supplied only when ordered: RS485 PC interface and PC software for online data recording
BOD-D Category:
Capacity, L

120, 210, 320, 500, 700

Power, W

1000, 1300, 1600, 2000, 2400

Chamber Size

450 × 450 × 600 mm, 600 × 600 × 600 mm, 600 × 600 × 900 mm, 650 × 650 × 1200 mm, 750 × 700 × 1350 mm

Shelves

2, 3, 4

Pack Size

1